Human HAV IgG

2013年12月11日 14:43:28人氣:252來源:上海逸峰生物科技有限公司

資料類型doc文件資料大小98816
下載次數33資料圖片 【點擊查看】
上 傳 人上海逸峰生物科技有限公司 需要積分0
關 鍵 詞Human ,HAV IgG
【資料簡介】

 

 

Human HAV IgG ELISA Kit

For the quantitative in vitro determination of Human hepatitis A virus IgG antibody concentrations in

 serum - plasma - celiac fluid - tissue homogenate - body fluid

 

 

 

 

FOR LABORATORY RESEARCH USE ONLY.

NOT FOR USE IN DIAGNOSTIC PROCEDURES.

 

 

 

This package insert must be read in its entirety before using this product.

 

ELISA

ENZYME LINKED IMMUNOSORBENT ASSAY

INTENDED USE AND TEST PRINCIPLE

This HAV IgG ELISA kit is intended Laboratory for Research use only and is not for use in diagnostic or therapeutic procedures. The Stop Solution changes the color from blue to yellow and the intensity of the color is measured at 450 nm using a spectrophotometer. In order to measure the concentration of HAV IgG in the sample, this HAV IgG ELISA Kit includes a set of calibration standards. The calibration standards are assayed at the same time as the samples and allow the operator to produce a standard curve of Optical Density versus HAV IgG concentration. The concentration of HAV IgG in the samples is then determined by comparing the O.D. of the samples to the standard curve.

 

SAMPLE COLLECTION AND STORAGES

Serum - Use a serum separator tube and allow samples to clot for 2 hours at room temperature or overnight at 4℃ before centrifugation for 20 minutes at approximay 2000×g. Remove serum and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles

Plasma - Collect plasma using heparin as an anticoagulant. Centrifuge samples for 30 minutes at 2000×g at 2-8℃ within 30 minutes of collection. Store samples at -20℃. Avoid repeated freeze-thaw cycles.

Cell culture supernates, tissue homogenate and other biological fluids - Remove particulates by centrifugation and assay immediay or aliquot and store samples at -20℃. Avoid repeated freeze-thaw cycles.

Note:  The samples shoule be centrifugated dequay and no hemolysis or granule was allowed.

 

MATERIALS REQUIRED BUT NOT SUPPLIED

1.  37 ℃ incubator

2.  Standard microplate reader capable of measuring absorbance at 450 nm

3.  Precision pipettes, disposable pipette tips and Absorbent paper

4.  Distilled or deionized water

 

REAGENTS PROVIDED

All reagents provided are stored at 2-8°C. Refer to the expiration date on the label.

 

Name

96 determinations

48 determinations

Microelisa stripplate

12*8strips

12*4strips

Standard6 vial

0.5ml/vial

0.5ml/vial

Sample diluent

6.0ml

3.0ml

HRP-Conjugate reagent

10.0ml

5.0ml

20X Wash solution

25ml

15ml

Chromogen Solution A

6.0ml

3.0ml

Chromogen Solution B

6.0ml

3.0ml

Stop Solution

6.0ml

3.0ml

Closure plate membrane

2

2

User manual

1

1

Sealed bags

1

1

Note:

1.  Standard concentration was followed by: 24001200600、300、150、75 IU/L.

2.  If samples generate values higher than the highest standard, please dilute the samples with Sample Diluent and repeat the assay.

 

PRECAUTIONS

1.         Do not substitute reagents from one kit lot to another. Standard, conjugate and microtiter plates are matched for optimal performance. Use only the reagents supplied by manufacturer.

2.         Allow kit reagents and materials to reach room temperature (20-25°C) before use. Do not use water baths to thaw samples or reagents.

3.         Do not use kit components beyond their expiration date.

4.         Use only deionized or distilled water to dilute reagents.

5.         Do not remove microtiter plate from the storage bag until needed. Unused strips should be stored at 2-8°C in their pouch with the desiccant provided.

6.         Use fresh disposable pipette tips for each transfer to avoid contamination.

7.         Do not mix acid and sodium hypochlorite solutions.

8.         Serum and plasma should be handled as potentially hazardous and capable of transmitting disease. Disposable gloves must be worn during the assay procedure, since no known test method can offer complete assurance that products derived from Rat blood will not transmit infectious agents. Therefore, all blood derivatives should be considered potentially infectious and good laboratory practices should be followed.

9.         All samples should be disposed of in a manner that will inactivate viruses.

10.     Liquid Waste: Add sodium hypochlorite to a final concentration of 1.0%. The waste should be allowed to stand for a minimum of 30 minutes to inactivate the viruses before disposal.

11.     Substrate Solution is easily contaminated. If bluish prior to use, do not use.

12.     Substrate B contain 20% acetone, keep this reagent away from sources of heat or flame.

13.     Remove all kit reagents from refrigerator and allow them to reach room temperature ( 20-25°C).

 

REAGENT PREPARATION AND STORAGE

Wash Solution (1X) - Dilute 1 volume of Wash solution (20X) with 19 volumes of deionized or distilled water. Wash Solution is stable for 1 month at 2-8°C.

 

ASSAY PROCEDURE

1.  Prepare all reagents before starting assay procedure. It is recommended that all Standards and Samples be added in duplicate to the Microelisa Stripplate.

2.  Add 50μl of Standard or Sample to the appropriate wells. Blank well doesn’t add anyting.

3.  Add 10l of HRP-conjugate reagent to standard wells and sample wells except the blank well, cover with an adhesive strip and incubate for 60 minutes at 37°C.

4.  Wash the Microtiter Plate 4 times.

Manual Washing - Remove incubation mixture by aspirating contents of the plate into a sink or proper waste container. Using a squirt bottle, fill each well compley with Wash Solution (1X), then aspirate contents of the plate into a sink or proper waste container. Repeat this procedure for a total of four times. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears. Note: Hold the sides of the plate frame firmly when washing the plate to assure that all strips remain securely in frame.

Automated Washing - Aspirate all wells, then wash plates four times using Wash Buffer (1X). Always adjust your washer to aspirate as much liquid as possible and set fill volume at 350μL/well/wash. After final wash, invert plate, and blot dry by hitting plate onto absorbent paper or paper towels until no moisture appears.

5.  Add chromogen solution A 50μl and chromogen solution B 50μl to each well. Gently mix and incubate for 15 minutes at 37°C. Protect from light.

6.  Add 50μl Stop Solution to each well. The color in the wells should change from blue to yellow. If the color in the wells is green or the color change does not appear uniform, gently tap the plate to ensure thorough mixing.

7.  Read the Optical Density O.D.) at 450 nm using a microtiter plate reader within 15 minutes.

 

CALCULATION OF RESULTS

1.         This standard curve is used to determine the amount in an unknown sample. The standard curve is generated by plotting the average O.D. (450 nm) obtained for each of the six standard concentrations on the vertical (X) axis versus the corresponding concentration on the horizontal (Y) axis.

2.         First, calculate the mean O.D. value for each standard and sample. All O.D. Values are subtracted by the mean value of the balnk well before result interpretation. Construct the standard curve using graph paper or statistical software.

3.         To determine the amount in each sample, first locate the O.D. value on the Y-axis and extend a horizontal line to the standard curve. At the point of intersection, draw a vertical line to the X-axis and read the corresponding concentration.

4.         Any variation in operator, pipetting and washing technique, incubation time or temperature, and kit age can cause variation in result. Each user should obtain their own standard curve.

5.         Intra-assay CV(%) and Inter-assay CV(%)are less than 15%.

6.         Assay range: 75 IU/L – 2400 IU/L.

7.  Sensitivity: The minimum detectable dose of Human HAV IgG is typically less than 10 IU/L.

8.  Cross-reactivity: This assay recognizes recombinant and natural Human HAV IgG. No significant cross-reactivity or interference was observed.

9.  Storage: 2-8℃ (Use frequently); six months (-20℃

10.  Standard curve

 

 

FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH ENTIRE PROCEDURE BEFORE BEGINNING!

 

上海逸晗生物科技有限公司代理不同品牌價格檔次的ELISA試劑盒。抗體產品等, 品種多,質量好,價格實惠,并且還提供免費代檢測服務。
本公司的更多產品,請點擊公司:http://www.yihanbio.com/

上海逸峰生物科技有限公司作者

上一篇:好的巖棉板都具有什么樣的特點

下一篇:解讀國標橡塑保溫板的用途是什么


我要投稿
  • 投稿請發送郵件至:(郵件標題請備注“投稿”)hbzhan@vip.qq.com
  • 聯系電話0571-87759680
環保行業“互聯網+”服務平臺
環保在線APP

功能豐富 實時交流

環保在線小程序

訂閱獲取更多服務

微信公眾號

關注我們

抖音

環保在線網

抖音號:hbzhan

打開抖音 搜索頁掃一掃

視頻號

環保在線

公眾號:環保在線

打開微信掃碼關注視頻號

快手

環保在線

快手ID:2537047074

打開快手 掃一掃關注
意見反饋
主站蜘蛛池模板: 久久福利一区二区 | 国产成人无码精品久久久小说 | 成品片a免人看免费 | 18以下岁禁止1000部免费 | 青青操网址| 草久影院 | 国产精品久AAAAA片 | 在线观看成人网 | 国产高清在线精品二区 | 一本久久a精品一合区久久久 | 国产毛片久久久久久久久春天 | av毛片在线观看地址 | 成人免费福利 | 一本到无码av专区无码不卡 | 久久久精品蜜桃 | 毛片网站视频 | 久久精品国产一区二区三区不卡 | 538在线一区二区精品国产 | 欧美日韩国产成人在线91 | 大地资源网免费观看高清 | 四面虎影最新播放网址 | 51视频国产精品一区二区 | 中文字幕无码人妻丝袜 | 27邪态恶动图gif喷水赞一把 | 乱人伦中文字幕无码 | 91视频.com| 日韩精品久久久免费观看四虎 | 古代性色禁片在线播放 | 久章草在线精品视频免费观看 | av网站在线观看免费 | 噜噜吧噜吧噜吧噜噜网A | 免费无码黄在线观看www | 国产精品丝袜肉丝出水 | 国产成人XXXXX免费视频 | 亚洲一区二区三区久久久 | 亚洲日本va中文字幕 | 久久夜色精品国产嚕嚕亚洲av | 五月天我淫我色 | 欧美另类一区 | 少妇高潮久久久久久潘金莲 | 亚洲一区二区欧美日韩 |